Aluminium curtain wall systems give architects more design flexibility than ever before. The right curtain walling not only enhances the look of a property, it is a vital component in building performance contributing to safety, comfort and light optimisation. But building performance is dependent on accurate installation. John McComb, Technical Director at Reynaers Aluminium UK, discusses how to demonstrate competency when it’s installed.

With a renewed emphasis on competency and accountability across the construction sector, product specification must ensure that systems such as curtain walling protect the integrity of a building from manufacture to installation. Identifying the right structural aluminium system that delivers thermal, weather and acoustic performance unlocks testing data and certification standards that in turn set out how the system must be installed.

The Building Safety Act (BSA) introduces new obligations to those involved in the design and construction of higher-risk buildings to demonstrate their professional competence.  Collaboration between all parties is vital to ensure system specification information is applied to projects at all stages and the highest standards of safety built into the fabric of the building from the outset.

Any ambiguities in design and specification, along with gaps in installation knowledge, challenge the success of this.

Meeting the standard

Although the BSA does not outline specific technical detail for the installation of curtain walling, it does reinforce the importance of compliance with existing regulations which are an essential, and legally binding requirement.

There are a robust set of building standards and guidelines that underpin best practice in curtain walling installation. These are supported by the Centre for Window and Cladding Technology (CWCT) and its ‘Standard for systemised building envelopes’ which outlines practical, industry-trusted guidance on design, installation and testing that helps to enhance the understanding of what regulatory compliance looks like.

In addition, British and European standards BS EN 13830, BS EN 1991 and BS EN 13116 outline essential performance and safety requirements that all systems must comply with. They mandate that curtain walls must withstand dead loads – their own weight, live loads – building movement, and meet deflection and anchorage criteria.

Alongside this, curtain walling must comply with stringent fire resistance specifications BS EN 13501-2018 when specified. As well as BS EN 1364-3 and BS EN 1364-4 for non-load bearing curtain walls to ensure insulation, integrity and radiation control are in place. Recent changes to UK Building regulations have seen a tightening of requirements around fire safety guidance including updates to Approved Document B, which requires stricter design measures and supporting evidence against materials used.

Enjoying this article? Sign up for our FREE newsletter!

Specification and verification

Understanding the specification needs of a project to ensure curtain walling performs as intended is the first stage of demonstrating competency. Does thermal performance mitigate the effects of external temperature variations? Do systems meet air, wind and water standards?

Verifying the installation process is non-negotiable when it comes to defining competence. A robust approach to documentation and verification to support the ‘golden thread’ is essential under the BSA, demanding comprehensive records, documentation and critical information is accessible to all.

Training and experience alongside a proactive and responsible industry culture is essential to developing and enhancing competency in the installation of curtain walling. Industry-recognised qualifications, such as the GQA for curtain walling, is just the starting point for what should be a career-long learning experience.

Specialist manufacturers, such as Reynaers, often offer their own training courses, which helps installers to keep up to date with the very latest systems, the best techniques for installing them and how product innovations can impact everything from specification to building occupancy. This is where collaboration and developing strong partnerships along the supply chain become crucial in demonstrating competence.

Project-specific approach

Going beyond the required inspections, by arranging collaborative checks with manufacturers and system providers, ensures products are installed to exact specification on that specific project. Digital tools further support best practice, enabling information sharing amongst stakeholders. This extends to capturing and sharing images of the installation to demonstrate competency.

Testing is also vital in demonstrating best practice in the use of curtain walling, providing evidence that gives regulators, clients and residents confidence in the safety, quality and performance of not only the facade, but the overall building.

Partnerships raise the competency bar

To elevate competency beyond compliance and demonstrate best practice in curtain walling installation it is essential stakeholders collaborate at every stage – from specification through to installation – meaning critical details become integrated from the offset, reducing the risk of non-compliance and costly rework. Only through an industry-wide shared commitment to best practice can competency in the installation of curtain walling be truly demonstrated.